model: sf3r350_6x8_10a_x | ![]() |
ordering code:b035x0608000c |
features |
applications |
standard size high current rating very fast response time stable performance over life very low capacitance high insulation resistance rohs-compatible |
modem xdsl-splitter data lines tuner antenna |
electrical specifications:
dc spark-over voltage1) 2) |
350 ± 20 |
v % |
impulse spark-over voltage2) |
||
100v/µs |
< 900 |
v |
1 kv/µs |
< 1000 |
v |
service life |
||
10 operations 50 hz, 1 s3) |
10 |
a |
1 operations 50 hz, 0.18 s (9 cycles)3) |
30 |
a |
10 operations[5x ( ) & 5x (-)] 8/20 µs3) |
10 |
ka |
1 operation 10/350 µs3) |
10 |
ka |
300 operations 10/1000 µs3) |
2 |
a |
insulation resistance at 25 vdc2) |
> 1 |
gω |
capacitance at 1 mhz 0.5v2) |
< 2 |
pf |
weight |
~1.5 |
g |
operation and storage temperature |
-40 ~ 90 |
°c |
marking |
3r 350 3r - 3 electrode |
|
350 - nominal voltage |
1) the voltage is measured with a low rate of rise dv / dt =100v/swww.ishumba.com
2) tip or ring electrode to center electrodewww.ishumba.com
3) total current through center electrode, half value through tip respectively ring electrode.www.ishumba.com
terms in accordance with gb/t 9043-2008 and itu-t rec. k.12.www.ishumba.com
dimensional drawing:
cautions and warnings:
- surge arresters must not be operated directly in power supply networks. www.ishumba.com
- surge arresters may become hot in case of longer periods of current stress (danger of burning). www.ishumba.com
-
surge arresters may be used only within their specified values. in case of overload, the head contacts may fail or the component may be destroyed.www.ishumba.com
-
damaged surge arresters must not be re-used.www.ishumba.com
![]() |
样本索取 | ![]() |