cs1a021b4k |
features ● measures ac, dc and impulse currents ● competitive cost/performance ratio ● low power consumption ● compact size ● high level of electrical isolation between primary and secondary circuits ● through-hole design (φ11mm), no insertion loss
typical applications ● variable speed drives ● current feedback control systems ● robotics ● ups & telecommunication power supplies ● welding power supplies ● automotive - battery management systems ●wattmeters |
|||
open-loop current sensor |
||||
description |
||||
the csa series are based on the principles of the hall-effect wherein a hall-effect device (hed) produces an output voltage linearly related to the amplitude and phase of a magnetic field applied to it. www.ishumba.com |
||||
electrical performance |
||||
nominal current (in) : |
20 |
a |
||
measuring range : |
70 |
a |
||
output resistance : |
≥ 2 |
kω |
||
nominal output voltage * : |
4 |
v |
||
supply voltage : |
±12 ~ ±15 (±5%) |
v |
||
supply current : |
15 |
ma |
||
isolation voltage : |
50 hz/ 1 min. 3 |
kv |
||
* the default output voltage is 4v, it will be adjusted according to customers’ requirements. |
||||
accuracy-dynamic performance |
||||
zero current offset : |
@ 25℃≤±20 |
mv |
||
residual offset after in: |
@ 25℃≤±20 |
mv |
||
thermal drift of offset : |
<± 10-3/ ℃ |
|||
thermal drift of gain : |
<± 2x10-4/ ℃ |
|||
linearity : |
± 1 |
%in |
||
response time : |
≤ 7 |
μs |
||
bandwidth : |
dc to 50 |
khz |
||
di/dt accuracy followed : |
50 |
a/ μs |
||
all specifications are at ±15 vdc supply and 25℃ [77°f] ambient temperature unless otherwise specificed. |
||||
general data |
||||
operating temperature : |
-10 ~ 80 |
℃ |
||
storage temperature : |
-25 ~ 85 |
℃ |
||
housing material : |
insulated plastic case |
|||
weight : |
36 typ. |
g |
||
mounting drawing in mm |